Page 382 - Pompy Dozujące 2021
P. 382

MAGNETIC-DRIVE CENTRIFUGAL PUMPS









             APPLICATIONS DB- AND SP-SERIES                      PROPERTIES AT A GLANCE
                                                                 DB- AND SP-SERIES
             •  Chemical processes
             •  Metal plating/working                            •  Close-coupled design
             •  Wastewater treatment                             •  Material PP or PVDF
             •  Electronics manufacturing                        •  Neodymium magnets on every model
             •  OEM equipment supply                             •  Replaceable shaft and bushing
             •  DI & High purity water                           •  ISO 1940 G2.5 balancing
             •  Fume scrubbing                                   •  Mounts to NEMA and IEC motor frames
             •  Mining                                           •  Easy Set measurement-free outer drive
             •  Paper mills                                      •  Mounts to motor without disassembly
             •  Pharmaceutical                                   •  Back pullout design
             •  Chillers                                         •  CE certified

                                                                 •  ATEX 2014/34/EU available (DB only)

             APPLICATIONS SP-SERIES
             •  Sumps
             •  Underground storage tanks                        SPECIFICATIONS
             •  Rail cars and tanker trucks
             •  Over-the-wall applications                       •  Up to 70% operating efficiency
             •  Double containment tanks                         •  Working pressure up to 6,2 bar (90 psi)
             •  Piping systems that tend to                      •  Maximum viscosity
                have trapped or entrained air.                      DB-Series: over 150 cP
                                                                    SP-Series: over 50 cP
                                                                 •  Maximum temperature
                                                                    PP: up to 82° C (180° F)
                                                                    PVDF: up to 104° C (220° F)



                                                                 TECHNICAL DATA

                                                                 •  SP retains fluid for re-priming when
                                                                    shut off without a check valve
                                                                 •  SP lifts up to 25 feet (7.6 meters)**
                                                                 •  SP primes up to 18 feet (5.5 meters)
                                                                    in 90 seconds***


                                                                 ** lift determined on fresh, cold water
                                                                 *** with maximum diameter impeller